Program Codes 422
EIA CODE DESCRIPTION
G211 Incremental Line In3
G212 Incremental CW Arc In3
G213 Incremental CCW Arc In3
G221 Absolute Line In2
G222 Absolute CW Arc In2
G223 Absolute CCW Arc In2
G231 Absolute Line In3
G232 Absolute CW Arc In3
G233 Absolute CCW Arc In3
G240 Programmable Kerf
G247 Table 1 Select
G248 Table 2 Select
G249 Table 3 Select
G250 Table 4 Select
G276 Internal Variable Load
G277 External Variable Load
G278 X Axis Home
G279 Y Axis Home
G280 X Home Return
G281 Y Home Return
M66 PLC Control Code
M75 Ignored if not using CBH, Tilt Rotator(s)
M76 Ignored if not using CBH, Tilt Rotator(s)
M210 X Sign Toggle
M211 Y Sign Toggle
M212 X and Y Swap and Toggle
M231 Aux. State Reset
M261 Aux. Torch Master On
M262 Aux. Torch Master Off
The unsupported EIA codes previously noted are ignored when read. Some of these codes may be
supported in the future. Any EIA codes that are not listed above will result in a translator error upon
loading the EIA program. Known EIA codes that will not be accepted include, but are not limited to:
Pvalue Program Number
Dvalue Indexed Kerf Operations
Vvalue Internal Variable Load
EIA Comments
Comments may be placed into the part program to be displayed on screen and viewed by the
operator. The comment line must first be preceded by a program stop command (EIA M00 code or
ESSI 0 code).
EIA Example:
M00 – Pauses Program
(Comment) – Text to be displayed