Diagnostics 292
Test All
Pressing the Test All soft key will send the selected output signal to all drive amplifiers.
Speed
The Speed window displays the current speed for each axis.
Note: When more than four axes are selected, the user will be prompted to select which group of
axes will be available for testing when entering the Drives & Motors Diagnostic screen,
SERCOS Drives & Motors
Use of the SERCOS Interface™ allows the user to easily expand the number of axes available for
use. The form of communication with the drives for Motion commands is over a serial link using
diagnostic software provided by the Drive vendor.
Warning! When sending direct signals to the drive amplifiers, unexpected motion on the cutting table
may occur and extreme caution should be used.
When the Drives and Motors screen has been pressed, the following warning message will appear.
When entering the Drive and Motors Diagnostics screen the specific drive communications software
will be launched for the drive being used. Please refer to information supplied by the Drive vendor on
how to use the drive setup software for the specific drive being used. The following are some
examples of drive setup and tuning software.

Table of Contents

Other manuals for Hypertherm MicroEdge

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm MicroEdge and is the answer not in the manual?

Hypertherm MicroEdge Specifications

General IconGeneral
BrandHypertherm
ModelMicroEdge
CategoryControl Systems
LanguageEnglish

Related product manuals