EasyManuals Logo
Home>Hypertherm>Control Systems>MicroEdge

Hypertherm MicroEdge User Manual

Hypertherm MicroEdge
574 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #73 background imageLoading...
Page #73 background image
Setups 49
Press the Timing Diagram soft key to view the timing diagram from setups.
Purge Time
Specifies the time delay for cutting gas purge before start of the laser cut motion is enabled.
New Gas Purge Time
Specifies the Gas Purge Time for switching from one cutting gas to another cutting gas.
Shutter Time
The Shutter Time parameter is used to specify the amount of time to open the shutter prior to the
laser beam on.
Power Ramp Time
The Power Ramp Time parameter is used to specify the amount of time to ramp up the laser power
prior to the laser pierce.
Pierce Time
Specifies the time delay from when laser head completes lowering until motion is initiated at creep
speed for cutting.
When Manual Pierce Control is selected, this is the total pierce time allowed.
With Automatic Pierce Control is selected, this time is an additional delay after pierce is complete.