EasyManuals Logo
Home>Keithley>Measuring Instruments>2601B

Keithley 2601B Reference Manual

Keithley 2601B
864 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #188 background imageLoading...
Page #188 background image
Series 2600B
System SourceMeter® Instrument Reference Manual Section 3:
Functions and features
2600BS-901-01 Rev. B / May 2013 3-53
The command queue can fill up with trigger entries if too many *TRG messages are received while a
test script is running, even if the script is processing triggers. You can avoid this by using the
localnode.prompts4882 attribute (see TSP command reference (on page 7-1) for more
information), and by using trigger.wait() calls that remove the *TRG messages from the
command queue. If the command queue fills with too many trigger entries, messages like abort will
not be processed.
Trigger generator
The Series 2600B has two trigger generators that can be used to generate trigger events. Use the
trigger.generator[N].assert()function to directly trigger events from the command interface
or a script (for example, you can trigger a sweep while the instrument is under script control).
The trigger.generator[N].EVENT_ID constant is an identification number that identifies events
generated by this generator. To have another trigger object respond to trigger events generated by
this generator, set the other object's stimulus attribute to the value of this constant.
Manual triggering
The TRIG key is used for manual triggering. Each time the TRIG key is pressed, a trigger event is
generated. You can monitor for a manual trigger event using the event ID
display.trigger.EVENT_ID. See Using the TRIG key to trigger a sweep (on page 3-39
) for an
example of how to use a manual trigger.
There are no action overruns for manual triggering.
Interactive triggering
The complexity of some test system configurations may not allow a static trigger setup. These
configurations would require more dynamic control of triggering than the static trigger setup provides.
For such cases, a setup providing interactive trigger programming would allow the generation and
detection of trigger events that can be controlled on demand under remote control. For example,
interactive triggering can be used when you need to make multiple source function changes or
implement conditional branching to other test setups based on recent measurements.

Table of Contents

Other manuals for Keithley 2601B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2601B and is the answer not in the manual?

Keithley 2601B Specifications

General IconGeneral
BrandKeithley
Model2601B
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals