System SourceMeter® Instrument Reference Manual Section 7:
2600BS-901-01 Rev. B / May 2013 7-289
Bit B7 B6 B5 B4 B3 B2 B1 B0
(2
) (2
) (2
) (2
) (2
) (2
) (2
) (2
)
Binary value 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1
Weights
(2
) (2
) (2
) (2
) (2
) (2
) (2
) (2
)
Example
status.operation.instrument.trigger_blender.trigger_overrun.enable
= status.operation.instrument.trigger_blender.trigger_overrun.BLND1
Uses a constant to set the bit for blender 1 of the operation status trigger blender overrun enable
register.
Also see
Operation Status Registers (on page E-9)
status.operation.instrument.trigger_blender.* (on page 7-286)
status.operation.instrument.trigger_timer.*
This attribute contains the operation status trigger timer summary register set.
Type TSP-Link accessible Affected by Where saved Default value
.event (R) Yes Status reset Not saved 0
Usage
operationRegister = status.operation.instrument.trigger_timer.condition
operationRegister = status.operation.instrument.trigger_timer.enable
operationRegister = status.operation.instrument.trigger_timer.event
operationRegister = status.operation.instrument.trigger_timer.ntr
operationRegister = status.operation.instrument.trigger_timer.ptr
status.operation.instrument.trigger_timer.enable = operationRegister
status.operation.instrument.trigger_timer.ntr = operationRegister
status.operation.instrument.trigger_timer.ptr = operationRegister
The status of the operation status trigger timer summary register; a zero (0)
indicates no bits set (also send 0 to clear all bits); the only valid value other than 0 is
1024