Section
8: Troubleshooting guide Series 2600B System SourceMeter® Instrument
Reference Manual
8-4 2600BS-901-01 Rev. B / May 2013
Error summary
Error number Error level Error Message
1113
RECOVERABLE
Data too complex
1200
RECOVERABLE
TSP-Link initialization failed
1202
RECOVERABLE
TSP-Link initialization failed
1203
RECOVERABLE
TSP-Link initialization failed (possible loop in node chain)
1204
RECOVERABLE
TSP-Link initialization failed
1205
RECOVERABLE
TSP-Link initialization failed (no remote nodes found)
1206 RECOVERABLE TSP-Link initialization failed
1207
RECOVERABLE
TSP-Link initialization failed
1208
RECOVERABLE
TSP-Link initialization failed
1209 RECOVERABLE TSP-Link initialization failed
1210
RECOVERABLE
TSP-Link initialization failed (node ID conflict)
1211 RECOVERABLE Node NN is inaccessible
1212
RECOVERABLE
Invalid node ID
1213
RECOVERABLE
TSP-Link session expired
1215
RECOVERABLE
Code execution requested within the local group
1216 RECOVERABLE
Remote execution requested on node in group with pending
overlapped operations
1217
RECOVERABLE
Remote execution requested on node outside the local group
1218
RECOVERABLE
Operation allowed only when TSP-Link master
1219
RECOVERABLE
TSP-Link found fewer nodes than expected
1400
RECOVERABLE
Expected at least NN parameters
1401
RECOVERABLE
Parameter NN is invalid
1402
RECOVERABLE
User scripts lost
1403 RECOVERABLE Factory scripts lost
1404
RECOVERABLE
Invalid byte order
1405
RECOVERABLE
Invalid ASCII precision
1406 RECOVERABLE Invalid data format
1500
RECOVERABLE
Invalid baud rate setting
1501
RECOVERABLE
Invalid parity setting
1502
RECOVERABLE
Invalid terminator setting
1503 RECOVERABLE Invalid bits setting
1504
RECOVERABLE
Invalid flow control setting
1600
RECOVERABLE
Maximum GPIB message length exceeded
1700
RECOVERABLE
Display area boundary exceeded
1800
RECOVERABLE
Invalid digital trigger mode
1801 RECOVERABLE Invalid digital I/O line
2000
SERIOUS
Flash download error
2001
RECOVERABLE
Cannot flash with error in queue
2101
FATAL
Could not close socket
2102
RECOVERABLE
Connection not established
2103
RECOVERABLE
Lan configuration already in progress
2104
RECOVERABLE
Lan disabled
2105
RECOVERABLE
Socket error
2106
RECOVERABLE
Unreachable gateway
2110
RECOVERABLE
Lan cable disconnected
2111
RECOVERABLE
Could not resolve hostname
2112 RECOVERABLE DNS name (FQDN) too long
2200
RECOVERABLE
File write error
2201
RECOVERABLE
File read error
2202 RECOVERABLE Cannot close file
2203
RECOVERABLE
Cannot open file

Table of Contents

Other manuals for Keithley 2601B