Page 1B-8 90-828631R3 MARCH 1999
Fuse Replacement – Electric Start Models
The electric starting circuit is protected from overload by an SFE 20 AMP fuse. If the fuse
is blown, the electric starter motor will not operate. Try to locate and correct the cause of
the overload. If the cause is not found, the fuse may blow again. Replace the fuse with a
fuse of the same rating.
1. Open the fuse holder and look at the silver colored band inside the fuse. If band is broken
replace the fuse. Replace fuse with a new fuse with the same rating.
a
a-Blown Fuse
Timing Belt Inspection
1. Inspect the timing belt and replace if any of the following conditions are found.
a. Cracks in the back of the belt or in the base of the belt teeth.
b. Excessive wear at the roots of the cogs.
c. Rubber portion swollen by oil.
d. Belt surfaces roughened.
e. Signs of wear on edges or outer surfaces of belt.
a
a-Timing Belt