NO
NO
YES
Is the
connection of indoor heat
ex
changer temperature thermistor
connector OK?
Are the
characteristics of indoor
heat exchanger temperature
thermistor OK?
YES
Temperature-resistance characteristic
Temperature sensor resistance (kΩ)
Temperature (°C)
15
10
5
0 10 30 4
020 50
Note (1) 22.5kΩ at -6
°C
5kΩ at 25
°C
Correct.

Connect
connector.
Defective indoor heat
exchanger temperature
thermistor

Replace.
Defective indoor control
PCB

Replace.
(Defective indoor heat
exchanger temperature
thermistor input circuit)
2. Error detection method
Anomalously low temperature
or high temperature (resistance)
is detected by the indoor heat
exchanger thermistor (Thi-R1,
R2 or R3).
3
.
Condition of error displayed
• When the temperature
thermistor detects -50°
C or lower for 5 seconds
continuously, the compressor
stops. After 3-minutes delay,
the compressor starts again
automatically, but if this
anomaly occurs again within
60 minutes after the initial
detection.
• Or if 70°C or higher is
detected for 5 seconds
continuously.
4. Presumable cause
• Defective indoor heat
exchanger thermistor
connector
• Defective indoor heat
exchanger thermistor
• Faulty indoor control PCB
Note: