Chapter 3 Configuring Your Library
Setting the Date, Time, and Time Zone
Scalar i500 User’s Guide 108
NTP is enabled on the Date & Time screen. When NTP is enabled, you
cannot manually configure date and time. For more information on
setting date and time manually, see Setting the Date and Time
Manually on page 107.
You can enter an IP address for a primary and an alternate (optional)
NTP server.
NTP server IP addresses must be entered in the proper format. See
Modifying Network Settings
on page 60 for the proper format of IPv4
and IPv6 addresses.
After you apply NTP settings, system clock synchronization may take
several minutes.
You can only enable and configure NTP on the Web client. The path to
open the appropriate screen is as follows:
From the Web client, select
Setup > Date & Time.
Setting the Time Zone 3
To select your time zone from a list, disable Use Custom Time Zone setting
and select your time zone.
If your time zone does not appear on the list, or you want more control
over your time settings, enable
Use Custom Time Zone and set a Universal
Coordinated Time (UTC) offset.
You can only set the time zone on the Web client. The path to open the
appropriate screen is as follows:
From the Web client, select
Setup > Date & Time.
Setting Daylight Saving
Time 3
If you selected your time zone from the drop-down list (see Setting the
Time Zone), the library automatically adjusts for daylight saving time.
There is no need to manually reset the clock for time changes.
However, if you set a custom time zone, the library will not automatically
adjust for daylight saving time. You must enable the
Use Custom Daylight
Saving Time
setting. Once enabled, you can set start and stop times to an
accuracy of one minute.
You can only set daylight saving time on the Web client. The path to open
the appropriate screen is as follows:
From the Web client, select
Setup > Date & Time.

Table of Contents

Other manuals for Quantum Scalar i500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum Scalar i500 and is the answer not in the manual?

Quantum Scalar i500 Specifications

General IconGeneral
BrandQuantum
ModelScalar i500
CategoryStorage
LanguageEnglish

Related product manuals