R5906848 /04 DP2K SLP Series152
13.1 Introduction to SCC file
Introduction
Barco has introduced the Spatial Color Calibration (SCC) file on the DP2K-SLP Series digital projectors. The
SCC file contains information to improve the color uniformity of the image. The uniformity is measured in the
factory and stored in a LUT-SCC file on the ICP board. This LUT-SCC file is activated on the projector at
factory.
Impact on service
As the LUT-SCC file is Light Processor specific, when replacing the Light Processor of the projector a new
LUT-SCC file has to be uploaded and set as active file. As the LUT-SCC file is stored on the Integrated
Cinema Processor (located on the ICMP or ICP board) the LUT-SCC file should be uploaded and activated
after replacement of the ICMP or ICP board.
This chapter explains how to obtain the correct LUT-SCC file and how to install it after having replaced the
Light Processor or ICMP/ICP.
Communicator version 4.7.8
(1)
or later is required to activate LUT-SCC files.
13.2 Obtain the Serial Number of the installed Light
Processor
The Serial Number of the installed Light Processor can be obtained in two different ways. Either by
reading it from the label on site or by reading it remotely using the Communicator software.
How to obtain the Serial Number of the installed Light Processor remotely?
1. Start up the Communicator software version 4.7.9
(2)
or later.
Note: The DP2K/DP4K software package version 1.11
(3)
or later must be installed to read out the
Light Processor serial via the Communicator.
2. Create a Diagnostic Package of the projector. For detailed instructions see User Guide of the Communicator
chapter “Diagnostic Package”.
3. Open the Diagnostic Package using Windows Explorer or the 'Diagnostic Package Reader' included in the PC
version of the Communicator software.
4. Look in the file/section “Hardware Info” for the serial number of the Light Processor.
Note: Only for recent Light Processors the serial number will be available in the Diagnostic Package.
For older Light Processors the serial number has to be read from the label (see below).
How to obtain the Serial Number of the installed Light Processor on site?
1. Remove the Lens from the projector.
2. Write down the Serial Number of the Light Processor. The label with Serial Number of the Light Processor
(reference 1 Image 13-1) is visible through the Lens Holder opening. The label is located at the front base of
the Light Processor.
Spatial Color Calibration (LUT-SCC)
1: For DP4K-P and DP2K-S the SCC functionality is already incorporate in the Communicator version 4.7.3
3: For DP4K-P and DP2K-S the SCC functionality is already incorporate in the DP2K/DP4K software package version 1.09.104