EasyManuals Logo
Home>Cisco>Network Router>7604

Cisco 7604 User Manual

Cisco 7604
1011 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #920 background imageLoading...
Page #920 background image
54-10
Cisco 7600 Series Router Cisco IOS Software Configuration Guide, Release 12.2SX
OL-4266-08
Chapter 54 Power Management and Environmental Monitoring
Understanding How Environmental Monitoring Works
Understanding How Environmental Monitoring Works
Environmental monitoring of chassis components provides early-warning indications of possible
component failures, which ensures a safe and reliable system operation and avoids network
interruptions. This section describes the monitoring of these critical system components, which allows
you to identify and rapidly correct hardware-related problems in your system.
Monitoring System Environmental Status
To display system status information, enter the show environment [alarm | cooling | status |
temperature] command. The keywords display the following information:
alarm—Displays environmental alarms.
status—Displays alarm status.
thresholds—Displays alarm thresholds.
cooling—Displays fan tray status, chassis cooling capacity, ambient temperature, and per-slot
cooling capacity.
status—Displays field-replaceable unit (FRU) operational status and power and temperature
information.
temperature—Displays FRU temperature information.
To view the system status information, enter the show environment command:
Router# show environment
environmental alarms:
no alarms
Router# show environment alarm
environmental alarms:
no alarms
Router# show environment cooling
fan-tray 1:
fan-tray 1 fan-fail: failed
fan-tray 2:
fan 2 type: FAN-MOD-9
fan-tray 2 fan-fail: OK
chassis cooling capacity: 690 cfm
ambient temperature: 55C ["40C (user-specified)" if temp-controlled]
chassis per slot cooling capacity: 75 cfm
module 1 cooling requirement: 70 cfm
module 2 cooling requirement: 70 cfm
module 5 cooling requirement: 30 cfm
module 6 cooling requirement: 70 cfm
module 8 cooling requirement: 70 cfm
module 9 cooling requirement: 30 cfm
Router# show environment status
backplane:
operating clock count: 2
operating VTT count: 3
fan-tray 1:
fan-tray 1 type: WS-9SLOT-FAN
fan-tray 1 fan-fail: OK
VTT 1:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco 7604 and is the answer not in the manual?

Cisco 7604 Specifications

General IconGeneral
BrandCisco
Model7604
CategoryNetwork Router
LanguageEnglish

Related product manuals