7.1 LAN IP address
7-14
1. Enable/Disable
This setting is made to set Enable/Disable for the VRRP function. Set Enable for both
No.1 and 2 FB-2000.
2. Name
Set the same name for No.1 and 2. You can set a name consisted of 50 characters at
maximum, and spaces cannot be used.
3. IP address
Set a common IP address for No.1 and 2 FB-2000. We will assume that this common
IP address is 192.168.1.3 here.
4. VRRP IP(1 –255)
Set the same ID number for both No.1 and 2.
5. VRRP Tx interval
This is the information exchange interval for confirming the connection status.
If there is no response from No.1 FB-2000 which is the equipment of the higher
priority, No.2 FB-2000 will backup the system to ensure the communication.
6. Priorty (1 – 254)
This setting is made to determine which will be prioritized between No.1 and 2. Set a
larger number for the equipment to be of higher priority.