10.7 LED and DIP Switch for the Communication unit
10-38
3. HUB Board LED
S2, 4:All OFF
Table 10.7.7 The LED for the HUB board
LED Description
CR4
CR4 (chip2012, GREEN): LED for debugging CPU
Turned off when CPU is not activated yet, blinking when CPU is activated.
[Detailed information]
In normal cases (All DIP-SWs are OFF)
The LED repeats being lighted -> turned off at an interval of 300 ms
When research / inspection mode is activated (DIP-SW 1 is set to ON)
The LED repeats 2-time blinking
When maintenance mode is activated (DIP-SW2 is set to ON)
The LED repeats 3-time blinking
When only the boot loader is activated
The LED repeats ON/OFF at an interval of 1 sec.
When the status does not change to normal mode, maintenance mode, or to
research / inspection mode.
When HUB CPU is activated (Linux activated), the LED will not have its status
changed.
It would take approx. 1 min. until the LED lighting operations described above
are established.
CR5
CR5 (chip2012, GREEN): The power indicator for the HUB board
Lighted when the power of the HUB board is turned on, and turned off when
the power of the HUB board is turned off.
CR15
CR15 (chip2012, GREEN): LED for debugging FPGA
Turned off when FPGA is not activated yet, and blinking after activated.
S2
S4
CR15
CR4
CR5

Table of Contents

Other manuals for Furuno FELCOM 250

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno FELCOM 250 and is the answer not in the manual?

Furuno FELCOM 250 Specifications

General IconGeneral
BrandFuruno
ModelFELCOM 250
CategoryMarine GPS System
LanguageEnglish

Related product manuals