Summary
12
5. Board Replacement
When you have replaced the board, confirm that no error message is being issued, and
then execute the communication test.
Exchanged
substrate
Treatment
Reference
page
Communication
unit
All settings for the Communication unit
Refer to
"4. Setup
Key
Points"
MODEM board
Settings -> Basic settings -> Serial port
Note)Replace the EEPROM with the original one.
6-1
HUB board
All settings for the Communication unit excluding those
described above.
Register the contacts in all Settings menu and in Contacts
menu.
Those listed below are mandatory in particular.
1) Settings -> Basic settings -> Analog ports
2) Settings -> PBX settings
3) Settings -> Network settings -> IP address ->
DHCP server -> USE
Note) Pay attention to terminals that are to have fixed IPs
allocated; stataic IP addresses can be set in
lease information.
4) Settings -> Network settings -> WAN
Note) Set the Streaming IP data by following the contract.
Refer to
"4. Setup
Key
Points"
Chapter 4
and 5
IF board No setting required
POWER board No setting required
Handset:
FB-8000
Display, Contacts, Sound, and Settings menu
Note) Contact: Only the contacts saved in the Handset
Setting for Settings -> SIP is mandatory in particular
4-31
Incoming
indicator:
FB-3000
No setting required
Analog phone:
FC755D1
Change the dialing method from DP (dial pulse) method to
PB (push button) method.
Dip SW -> #1 ON
4-33
FAX:
FAX-2810
FAX-2820
Initialize EEPROM and confirm ON/OFF status for ECM and
the MODEM settings. These settings are to be changed
according to the communication status.
4-34
Antenna unit:
FB-1500
FB-1250
No setting required