EasyManuals Logo
Home>Furuno>Marine GPS System>FELCOM 250

Furuno FELCOM 250 Service Manual

Furuno FELCOM 250
462 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #403 background imageLoading...
Page #403 background image

Appendix 2. Message List
AP2-20
AP2.3.2 Forward the System Log
You can forward the Error, Warning, and Notice messages to the network equipment of
the specified IP address.
x Protocol: UDP
x Receiving port number: 514
Since the IP addresses will be automatically allocated by the DHCP server, it is
recommended to have a static IP address set for the forwarding target network terminal,
such as the Syslog server.
Procedure)
This document is described based on the assumption that “GSTsyslogd005” for Syslog
server is installed in the PC.
“GSTsyslogd005” is a freeware. You can search for it with “GSTsyslog” and download
the software.
** Using fixed IP addresses **
Please refer to page 7-7. The description below is based on the assumption that the IP
address is fixed by the PC and not using the DHCP server of the Communication unit.
1. As for the PC setting, select local area connection, and open Internet protocol
(TCP/IP) -> Properties, place a tick in “Use the following IP address”, and set the
following IP address.
- IP Address : Set the IP address within the range of 192.168.1.2 to
192.168.1.9
- Subnet Mask : 255.255.255.0
- Default Gateway : 192.168.1.1 -> Own IP address
2. Place a tick for “Use the following DNS server address”, and enter the IP address.
- DNS Servers : 192.168.1.1 -> Own IP address

Table of Contents

Other manuals for Furuno FELCOM 250

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno FELCOM 250 and is the answer not in the manual?

Furuno FELCOM 250 Specifications

General IconGeneral
BrandFuruno
ModelFELCOM 250
CategoryMarine GPS System
LanguageEnglish

Related product manuals