Appendix 2. Message List
AP2-3
AP2.2 Message List
The message descriptions;
The structure of Error “9101: (ADE) Cable calibration fault”.
x Error : Message type (Error, Warning, Notice)
x 9101 : Error number
x (ADE) : The part where the Error was detected
x Cable calibration fault. : The message output
1. Error 9001: (ADE) Connection failure between Comm. Unit and Ant. Unit.
The status for this error is constantly confirmed at an interval of 1 to 3 seconds.
The error would occur when communication with ADE is unavailable. Please confirm
the connection and cable between ADE and BDE. It may also imply a failure in the
ATB Module. If that is the case, replace the Front end Module (ATB & LNA).
2. Notice 9002: (ADE) AZ motor: Short circuit detected.
The status for this error is confirmed when the system is activated/during selftest.
This will be output when AZ motor is being short out with the power source. Please
confirm the connection between the ATB Module and the AZ motor. It may also
imply a failure in the ATB Module. If that is the case, replace the Front end Module
(ATB & LNA).
Note) If the Antenna is operating in a normal manner, the error may be a false
detection.
3. Notice 9003: (ADE) AZ motor: Short detected.
The status for this error is confirmed when the system is activated/during selftest.
This will be output when AZ motor is being short out with the GND.
Please confirm the connection between the ATB Module and the AZ motor. It may
also imply a failure in the ATB Module. If that is the case, replace the Front end
Module (ATB & LNA).
Note) If the Antenna is operating in a normal manner, the error may be a false
detection.
4. Notice 9004: (ADE) AZ motor: Undervoltage lockout, overvoltage lockout,
overtemperature, low load current or shorted load.
The status for this error is confirmed when the system is activated/during selftest.
This will be output when abnormality is detected for the voltage, current, or
temperature of the AZ motor. This message will also be displayed when the motor
cable is disconnected. Please confirm the connection between the ATB Module and
the AZ motor. It may also imply a failure in the ATB Module.
If that is the case, replace the Front end Module (ATB & LNA).
Note) If the Antenna is operating in a normal manner, the error may be a false
detection.