EasyManuals Logo
Home>Furuno>Marine GPS System>FELCOM 250

Furuno FELCOM 250 Service Manual

Furuno FELCOM 250
462 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #406 background imageLoading...
Page #406 background image
Appendix 3. Specifications
AP3-2
4. INTERFACE
4.1 Ethernet 4 ports: RJ-45, 10base-T or 100base-TX,
PSE class 0 (power supply: 30 W max.)
4.2 Analog telephone/telefax 4 ports: RJ-11 (2), Phoenix connector 4P (2)
4.3 RS-232C 1 port: Dsub-9P
4.4 Output alarm 1 port: contact closure (normal close),
Phoenix connector 2P
4.5 Navigation data input 1 port: IEC61162-1, Phoenix connector 5P
4.6 L-band output 1 port: BNC
4.7 SIM card slot 1
5. POWER SUPPLY
5.1 Communication unit 12-24 VDC: 9.2-4.6 A (TX), 2.0-1.0A (RX)
5.2 Handset PD class 2, 5 W or less
5.3 Incoming indicator PD class 1, 2 W or less
5.4 AC/DC power supply unit (PR-240, option)
100-115/200-240 VAC, 1 phase, 50/60Hz
6. ENVIRONMENTAL CONDITION
6.1 Ambient temperature
Exposed equipment: -25°C to +55°C (storage: -35°C to +70°C)
Protected equipment: -25°C to +55°C
6.2 Relative humidity 95% at 40°C
6.3 Degree of protection
Antenna unit IP56
Communication unit IPX0
Handset IP22 (cradle: IPX0)
Incoming indicator IPX0
6.4 Vibration IEC 60945
6.5 Motion Roll: ±30°/8s, Pitch: ±10°/6s, Yaw: ±8°/50s,
Rotation: 6°/s, Speed: 30kt
7. UNIT COLOR
7.1 Antenna unit N9.5
7.2 Communication unit N2.5
7.3 Handset/ cradle N2.5
7.4 Incoming indicator N2.5

Table of Contents

Other manuals for Furuno FELCOM 250

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno FELCOM 250 and is the answer not in the manual?

Furuno FELCOM 250 Specifications

General IconGeneral
BrandFuruno
ModelFELCOM 250
CategoryMarine GPS System
LanguageEnglish

Related product manuals