Appendix 3. Specifications
AP3-4
4. INTERFACE
4.1 Ethernet 4 ports, 10base-T or 100base-TX,
PSE class 0 (total up to 30.8 W)
4.2 Analog telephone/telefax 4 ports
4.3 RS-232C 1 port
4.4 Output alarm 1 port, contact closure (normal close/open)
4.5 Navigation data input 1 port, IEC61162-1
4.6 L-band output 1 port
4.7 SIM card slot 1
5. POWER SUPPLY
5.1 Communication unit 12-24 VDC: 9.2-4.6 A (TX), 2.0-1.0 A (RX)
5.2 Handset PD class 2, 5 W or less
5.3 Incoming indicator PD class 1, 2 W or less
5.4 AC/DC power supply unit (PR-240, option)
100-115/200-240 VAC, 1 phase, 50/60Hz
6. ENVIRONMENTAL CONDITION
6.1 Ambient temperature
Exposed equipment: -25°C to +55°C (storage: -35°C to +70°C)
Protected equipment: -25°C to +55°C
6.2 Relative humidity 95% at 40°C
6.3 Degree of protection
Antenna unit IP56
Communication unit IPX0
Handset IP22 (cradle: IPX0)
Incoming indicator I PX0
6.4 Vibration IEC 60945
6.5 Motion Roll: ±30°/8s, Pitch: ±10°/6s, Yaw: ±8°/50s,
Rotation: 6°/s, Speed: 30kt
7. UNIT COLOR
7.1 Antenna unit N9.5
7.2 Communication unit N2.5
7.3 Handset/ cradle N2.5
7.4 Incoming indicator N2.5

Table of Contents

Other manuals for Furuno FELCOM 250

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno FELCOM 250 and is the answer not in the manual?

Furuno FELCOM 250 Specifications

General IconGeneral
BrandFuruno
ModelFELCOM 250
CategoryMarine GPS System
LanguageEnglish

Related product manuals