Program Codes 418
EIA CODE DESCRIPTION
G41 D1-200 Enables Left Kerf using a Kerf Table variable
G42 D1-200 Enables Right Kerf using a Kerf Table variable
G43 D1-200 Sets the current Kerf value via the Kerf Table using prior set Left / Right Kerf
G59 D1-200Xvalue Sets Kerf table variable from 1-200
G59 Vvalue Fvalue Sets the Plasma Supply current through Outputs or Serial Link for Vprocess
(504,514,524,534) at Fcurrent value
V504 Current Setting Plasma 1
V514 Current Setting Plasma 2
V524 Current Setting Marker 1
V534 Current Setting Marker 2
G66 Dval Bval Cval Auto Align 3 Point Method with Long Offset Distance, Fast Speed, Slow
Speed values respectively
G82 Oxy-Fuel Cut Mode
G83 Oxy-Fuel Cut Mode Contour Bevel Head
G84 Plasma Cut Mode
G85 Plasma Cut Mode Contour Bevel Head
G90 Absolute Programming Mode
G91 Incremental Programming Mode
G92 Set Axis Presets
G97 Program Repeat Pointer
G97 Tvalue Program Repeat Pointer. Executes the repeat T times
G98 Repeat at G97, or start of program if no G97
G99 Part Options
M00 Program Stop
M01 Optional Program Stop (uses Setup Parameter)
M02 End of Program
M07 Cutting Device On
M08 Txx.xx Cutting Device Off (Temporary Optional Time Delay from 1 to 99.99
seconds)
M09 Enable Marker 1
M10 Disable Marker 1
M11 Marker Offset 1 On
M12 Marker Offset 1 Off
M13 Enable Marker 2
M14 Disable Marker 2
M15 Cut On
M16 Cut Off
M17 Oxy Gas On
M18 Oxy Gas Off
M19 Cancel All Stations
M26 Station Select On
M27 Station Select Off
M28 CBH / Rotator(s) Disable
M29 CBH / Rotator(s) Enable
M30 End of Program (same as M02)
M31 Reset Functions (Cut Off, Marker Off, Kerf Off)
M32 Unclamp / Unlock All Stations
M32 Tvalue Unclamp / Unlock „T” Station, where T = 1 through 19
M33 Unclamp / Lock All Stations
M34 Clamp / Unlock All Stations
M34 Tvalue Clamp / Unlock „T” Station, where T = 1 through 19
M35 Clamp / Unlock All Stations Mirror
M35 Tvalue Clamp / Unlock Mirror “T” Station, where T = 1 through 19

Table of Contents

Other manuals for Hypertherm MicroEdge

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm MicroEdge and is the answer not in the manual?

Hypertherm MicroEdge Specifications

General IconGeneral
BrandHypertherm
ModelMicroEdge
CategoryControl Systems
LanguageEnglish

Related product manuals