SAFETY
PRECAUTIONS FOR OPERATION
STARTING WITH BOOSTER CABLE
If any mistake is made in the method of connecting the booster
cables, it may cause the battery to explode, so always do as
follows.
When starting with a booster cable, carry out the starting
operation with two workers (one worker sitting in the operator's
seat and the other working with the battery).
When starting from another machine, do not allow the two
machines to touch.
When connecting the booster cables, turn the starting switch
OFF position for both the normal machine and problem
machine. There is a hazard that the machine will move when the
power is connected.
Be sure to connect the positive (+) cable first when installing the
booster cables. Disconnect the negative (-) cable (ground side)
first when removing them.
When removing the booster cables, be careful not to let the
booster cable clips touch each other or to let the clips touch the
machine.
Always wear safety glasses and rubber gloves when starting the
engine with booster cables.
When connecting a normal machine to a problem machine with
booster cables, always use a normal machine with the same
battery voltage as the problem machine.
For the procedure of starting the engine with booster cables, see
"STARTING ENGINE WITH BOOSTER CABLE (PAGE
3-146)".