OPERATION
OPERATION
STOPPING ENGINE
NOTICE
If the engine is stopped without allowing it to cool down, there is danger
that the service life of various parts of the engine will be reduced. Except
in emergencies, never stop the engine suddenly.
If the engine overheats, do not stop it suddenly. Run it at low speed to
allow it to cool down gradually, then stop it.
1.
Lower the work equipment to the ground.
2. Turn fuel control dial (1) in the low idling (MIN) positions and
run the engine at low idling speed for 5 minutes to allow the
engine to gradually cool down.
3.
Turn the key in starting switch (2) to the OFF position.
The engine will stop.
REMARK
When the key in starting switch (2) is turned to the OFF position,
the engine stops, but the machine power supply is not cut
immediately.
The power supply is maintained for several seconds to enable
the controller to save the operating condition to memory and
shuts down the system after that. The length of time that the
power supply is maintained depends on the operating
condition.
Even when the cooling fan is being operated in reverse or in the
cleaning mode, the machine power supply is not cut
immediately when the key in starting switch (2) is turned to the
OFF position.
The power supply is maintained for seven seconds to protect
the hydraulic circuit. During that time, the fan operation
confirmation lamp on the monitor panel flashes.
4. Remove the key from starting switch (2).
3 - 103