110Service Manual – SC5000 24 - Electrical System
Battery Charger Error Codes
8-E001 High battery voltage
Description Battery voltage too high.
Setting
Conditions
The battery voltage is higher than the software setting.
When Monitored
Charging
Possible Causes
Initial Action
Troubleshooting Steps
• Check the battery voltage and cable connections.
• Check battery size and condition.
• This error will automatically clear once the condition has been corrected.
8-E002 Low battery voltage
Description Battery voltage too low to start a charge cycle.
Setting
Conditions
Algorithm dependent – typically 0.1V/cell.
When Monitored
Charging
Possible Causes
Initial Action
Troubleshooting Steps
• Check the battery voltage and cable connections.
• Check battery size and condition. Batteries may be overdischarged.
• Use another charger to bring the batteries above the minimum voltage.
• This error will automatically clear once the condition has been corrected.