2-223
2 Instruction Descriptions
NJ-series Instructions Reference Manual (W502)
BCD Conversion Instructions
2
BCDsToBin
• Use the same sizes of data types for In and Out.
• An error occurs in the following cases. ENO will be FALSE, and Out will not change.
• The value of Format is _BCD0 and the upper digit of In is 2 to F.
• The value of Format is _BCD2 and the upper digit of In is A to E.
• The value of Format is _BCD3 and the upper digit of In is B to E.
• Except for the above conditions, any digit in In is A to F.
• The value of Format is outside of the valid range.
Precautions for Correct Use