2 Instruction Descriptions
2-252
NJ-series Instructions Reference Manual (W502)
The following table shows the valid ranges for In and Out according to their data types.
To convert data with any data type to a real number, use a TO_** (Real Number Conversion Group)
instruction (page 2-281).
• Always use the correct instruction name for the data types of In and Out.
• If the value of In is positive or negative infinity, the value of Out is positive or negative infinity.
• If the value of In is nonnumeric data, the value of Out is nonnumeric data.
• If the conversion result exceeds the valid range of Out, the value of Out will be infinity with the same
sign as the value of In.
• For the LREAL_TO_REAL instruction, if the value of In is closer to 0 than ±1.175494e−38, the value
of Out will be 0.
Data type of In Data type of Out Valid range for In and Out
REAL LREAL −3.402823e+38 to 3.402823e+38
or +∞/−∞
LREAL REAL
Additional Information
Precautions for Correct Use
In
Out=abc
REAL data
LREAL data
REAL#3.141592e+0
3.141592e+0