11.7 F: OPTIONS
422 SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
No.
(Hex.)
Name Description
Default
(Range)
Ref.
F3-17
(0BEA)
Expert
D7 Function Selection
Sets the function for terminal D7 of the DI-A3 when F3-01 = 8 [D.In Funct Selection =
MF Digital Input].
0
(0 - 4, 6 - 19F)
640
F3-18
(0BEB)
Expert
D8 Function Selection
Sets the function for terminal D8 of the DI-A3 when F3-01 = 8 [D.In Funct Selection =
MF Digital Input].
0
(0 - 4, 6 - 19F)
640
F3-19
(0BEC)
Expert
D9 Function Selection
Sets the function for terminal D9 of the DI-A3 when F3-01 = 8 [D.In Funct Selection =
MF Digital Input].
0
(0 - 4, 6 - 19F)
640
F3-20
(0BED)
Expert
DA Function Selection
Sets the function for terminal DA of the DI-A3 when F3-01 = 8 [D.In Funct Selection
= MF Digital Input]
0
(0 - 4, 6 - 19F)
641
F3-21
(0BEE)
Expert
DB Function Selection
Sets the function for terminal DB of the DI-A3 when F3-01 = 8 [D.In Funct Selection
= MF Digital Input].
0
(0 - 4, 6 - 19F)
641
F3-22
(0BEF)
Expert
DC Function Selection
Sets the function for terminal DC of the DI-A3 when F3-01 = 8 [D.In Funct Selection
= MF Digital Input].
0
(0 - 4, 6 - 19F)
641
F3-23
(0BF0)
Expert
DD Function Selection
Sets the function for terminal DD of the DI-A3 when F3-01 = 8 [D.In Funct Selection
= MF Digital Input].
0
(0 - 4, 6 - 19F)
641
F3-24
(0BF1)
Expert
DE Function Selection
Sets the function for terminal DE of the DI-A3 when F3-01 = 8 [D.In Funct Selection =
MF Digital Input].
0
(0 - 4, 6 - 19F)
641
F3-25
(0BF2)
Expert
DF Function Selection
Sets the function for terminal DF of the DI-A3 when F3-01 = 8 [D.In Funct Selection =
MF Digital Input].
0
(0 - 4, 6 - 19F)
641
F4: ANALOG OUTPUT
No.
(Hex.)
Name Description
Default
(Range)
Ref.
F4-01
(0391)
Term.V1 Funct Selection
Sets the monitor signal output from terminal V1.
102
(000 - 999)
642
F4-02
(0392)
RUN
Term.V1 Gain
Sets the gain of the monitor signal that is sent from terminal V1. Sets the analog signal
output level from the terminal V1 at 10 V or 20 mA as 100% when an output for
monitoring items is 100%.
100.0%
(-999.9 - +999.9%)
642
F4-03
(0393)
Term.V2 Function
Selection
Sets the number for monitor item of output from terminal V2.
103
(000 - 999)
642
F4-04
(0394)
RUN
Term.V2 Gain
Sets the gain of the monitor signal that is sent from terminal V2.
When an output for monitoring items is 0%, this parameter sets the analog signal output
level from the V2 terminal at 10 Vor 20 mA as 100%.
50.0%
(-999.9 - +999.9%)
643
F4-05
(0395)
RUN
Term.V1 Bias
Sets the bias of the monitor signal that is sent from terminal V1. Set the level of the
analog signal sent from the V1 terminal at 10 Vor 20 mA as 100% when an output for
monitoring items is 0%.
0.0%
(-999.9 - +999.9%)
643
F4-06
(0396)
RUN
Term.V2 Bias
Sets the bias of the monitor signal that is sent from terminal V2. Set the level of the
analog signal sent from the V2 terminal at 10 Vor 20 mA as 100% when an output for
monitoring items is 0%.
0.0%
(-999.9 - +999.9%)
643
F4-07
(0397)
Term.V1 Level of Signal
Sets the output signal level for terminal V1.
0 : 0 to 10V
1 : -10 to 10V
0
(0, 1)
643
F4-08
(0398)
Term.V2 Level of Signal
Sets the output signal level for terminal V2.
0 : 0 to 10V
1 : -10 to 10V
0
(0, 1)
643

Table of Contents

Other manuals for Omron Q2A Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron Q2A Series and is the answer not in the manual?

Omron Q2A Series Specifications

General IconGeneral
BrandOmron
ModelQ2A Series
CategoryController
LanguageEnglish

Related product manuals