■ F4-04 Term.V2 Gain
No.
(Hex.)
Name Description
Default
(Range)
F4-04
(0394)
RUN
Term.V2 Gain
Sets the gain of the monitor signal that is sent from terminal V2.
50.0%
(-999.9 - +999.9%)
The maximum output voltage output from terminal V2 is ±10 V. Use F4-08 [Term.V2 Level of Signal] to set the
signal level.
Example settings:
When you use these settings, and the monitored output voltage is at 100% (drive rated current), the output voltage
of terminal V2 is 5 V (50% of 10 V). The output current is 200% of the drive rated current when terminal V2
outputs a maximum voltage of 10 V.
• F4-03 [Term.V2 Function Selection] = 103 (U1-03: Output Current)
• F4-04 = 50.0%
• F4-06 [Term.V2 Bias] = 0.0%
• F4-08 = 0 (0 to 10V)
■ F4-05 Term.V1 Bias
No.
(Hex.)
Name Description
Default
(Range)
F4-05
(0395)
RUN
Term.V1 Bias
Sets the bias of the monitor signal that is sent from terminal V1. Set the level of the analog signal
sent from the V1 terminal at 10 Vor 20 mA as 100% when an output for monitoring items is 0%.
0.0%
(-999.9 - +999.9%)
The maximum output voltage output from terminal V1 is ±10 V. Use F4-07 [Term.V1 Level of Signal] to set the
signal level.
■ F4-06 Term.V2 Bias
No.
(Hex.)
Name Description
Default
(Range)
F4-06
(0396)
RUN
Term.V2 Bias
Sets the bias of the monitor signal that is sent from terminal V2. Set the level of the analog signal
sent from the V2 terminal at 10 Vor 20 mA as 100% when an output for monitoring items is 0%.
0.0%
(-999.9 - +999.9%)
The maximum output voltage output from terminal V2 is ±10 V. Use F4-08 [Term.V2 Level of Signal] to set the
signal level.
■ F4-07 Term.V1 Level of Signal
No.
(Hex.)
Name Description
Default
(Range)
F4-07
(0397)
Term.V1 Level of Signal
Sets the output signal level for terminal V1.
0
(0, 1)
0 : 0 to 10V
1 : -10 to 10V
■ F4-08 Term.V2 Level of Signal
No.
(Hex.)
Name Description
Default
(Range)
F4-08
(0398)
Term.V2 Level of Signal
Sets the output signal level for terminal V2.
0
(0, 1)
0 : 0 to 10V
1 : -10 to 10V
◆ F5: DIGITAL OUTPUT