Chapter 6: Performing Library Operations
Performing Media Operations
Quantum Scalar i40 and Scalar i80 User’s Guide 157
Moving cartridges using the library Web client may necessitate
performing an inventory on your host system. You can also move
cartridges using your host application. See your host application
documentation for more information.
If the partition is online, it will be taken offline before the move is
performed and brought back online after the move is complete. You
will be asked to confirm that you want to take the partition offline.
You can select only the partitions to which you have been given
access.
You cannot move media directly from one partition to another.
You can only perform move commands from the Web client.
Web Client
1 Select Operations > Media > Move.
2 If more than one partition exists, select the partition that contains
the cartridge you want to move and click Next.
The Move Media -
Partition (Mode)
screen displays, where
Partition
is the name of the partition and
Mode
is the current mode
of the partition.
3 In the Select Media section, select the source cartridge you want to
move.
Note: You can use the Filter by Barcode text box to filter the
available cartridge barcodes. Click the Help button next to
the Find button for more information about filtering
barcodes. In addition, if not all cartridges appear on the
screen, use the Page 1 of x arrows to view the additional
cartridges.
Note: Bold column headings in the table can be sorted. For
example, selecting the Location column heading will sort
by location coordinates.
4 In the Select Destination section, select a destination location for
the source cartridge.
5 Click Apply.

Table of Contents

Other manuals for Quantum Scalar i40

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum Scalar i40 and is the answer not in the manual?

Quantum Scalar i40 Specifications

General IconGeneral
Power requirements100 - 240 V AC, 50 - 60 Hz, 2.8/1.4 Amps
Power consumption (typical)100 W
Expansion slots25
Dimensions (WxDxH)455 x 793 x 132 mm
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)10 - 35 °C
Operating relative humidity (H-H)20 - 80 %
Media typeTape Cartridge
Product typeStorage auto loader & library
Product colorBlack
Weight and Dimensions IconWeight and Dimensions
Weight15800 g

Related product manuals