Chapter 9: Installing, Removing, and Replacing Components
Installing the Library In a Rack
242 Quantum Scalar i40 and Scalar i80 User’s Guide
2 Lift the library, place it on the rack shelves, and slide it into the rack
as far as it will go.
3 Open one of the magazines slightly to access the captive
thumbscrew that is attached to the library chassis. You will use this
thumbscrew to secure the library to the rack. To open the magazine,
insert the magazine lock override tool into the access hole in the
bottom of the magazine bezel (see Figure
50 on page 242). Use the
tool to depress the release latch while gently pulling outward on the
magazine bezel hand
le.
Right-side magazines will only slide out as far as the I/E station (one
column
of slots). To release the right-side magazines fully:
• On the Scalar i40 and the bottom right magazine
of the Scalar
i80, reach under the open magazine and insert the tool directly
into the access hole in the library chassis to depress the release
latch, while pulling out on the magazine bezel handle.
• On the top right magazine of the Scal
ar i80, reach under the
open magazine and press the release latch directly with your
finger, while pulling out on the magazine bezel handle.
Figure 50 Magazine Release
Latch Access Holes
4 Screw the captive thumbscrew finger-tight into the rack (and
through the clip nut or cage nut, if installed). See Figure
51 on
page 243.
5 Repea
t Step 3 and Step 4 for the remaining thumbscrews.
6 C
lose all the magazines by pushing them in until they click shut.