Chapter 8: Getting Information About the Library
Viewing the Location of the Robot
Quantum Scalar i40 and Scalar i80 User’s Guide 207
• Encryption (this section displays only if encryption key management
is licensed and configured on the library) — Key server type;
encryption software version; SSL connection (enabled/disabled);
primary host (primary key server IP address or host name), primary
key server port number; primary key server serial number; secondary
host (secondary key server IP address or host name); secondary key
server port number; secondary key server serial number.
• Library Partitions — Name, serial number, control path, online/
offline status, encryption method, encryption type, number of
storage slots, number of media, and number of tape drives
configured for each partition.
• Drives — Location coordinates, vendor, model, type, serial number,
physical serial number (P-SN), logical serial number (L-SN), firmware
level, and encryption method.
Operator Panel
1 Select Reports > About Library.
2 Press Next to scroll through all the screens. Press Exit to exit at any
time.
Web Client
Select Reports > System Information.
Viewing the Location of the Robot
You can set the operator panel to view the robot position as library
operations are performed. This view is helpful in diagnosing any library
problems because you can see where the robot is, whether it contains a
tape, and the finger position.
If you perform an operation from the remote interface, the operator
panel displays the operation as it is performed. If you perform an
operation from the operator panel, once complete, you can return to
the Robot View to view the completed operation status.