Chapter 4: Configuring the Library
Working With Partitions
54 Quantum Scalar i40 and Scalar i80 User’s Guide
Operator Panel
1 Select Setup > Configure Partitions > Auto-Create Partitions.
2 Use the Up and Down buttons to select the number of partitions
you want to create. (If the Up and Down buttons are not available,
you do not have available resources. Modify or delete partitions to
create resources.)
3 Press Apply.
4 Save the library configuration (see Saving the Library Configuration
on page 107).
Web Client
1 Select Setup > Partitions.
2 Click Automatic. (If the Automatic button is not visible, you do not
have available resources. Modify or delete partitions to create
resources.)
The Automatically Create Partitions screen displays.
By default, the library applies the Scalar i40-i80 library emulation
type and Standard media barcode format to each partition. You can
change these settings by modifying the partition after it has been
created (see
Modifying Partitions on page 56).
3 Using the Partitions drop-down list, select the number of partitions
to create.
4 Click Apply.
5 Save the library configuration (see Saving the Library Configuration
on page 107).
Manually Creating
Partitions
You can manually create partitions any time after the initial
configuration of the library. The maximum number of partitions that can
be created is equal to the number of tape drives in the library.
The library must contain at least one unallocated tape drive and one
unallocated slot to manually create a partition. If no unallocated tape
drives or slots exist, you must modify or delete partitions to free
resources. For more information, see
Modifying Partitions on page 56
and Deleting Partitions on page 57.

Table of Contents

Other manuals for Quantum Scalar i40

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum Scalar i40 and is the answer not in the manual?

Quantum Scalar i40 Specifications

General IconGeneral
Power requirements100 - 240 V AC, 50 - 60 Hz, 2.8/1.4 Amps
Power consumption (typical)100 W
Expansion slots25
Dimensions (WxDxH)455 x 793 x 132 mm
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)10 - 35 °C
Operating relative humidity (H-H)20 - 80 %
Media typeTape Cartridge
Product typeStorage auto loader & library
Product colorBlack
Weight and Dimensions IconWeight and Dimensions
Weight15800 g