10-38 2000-OSM, F1
GCC Commands and Functions
ACT(stream%) ACTIVE STREAM
ACTIVATED_BY ACTIVATED BY
ALARM ALARM
ASSIGN(stream%,method%) ASSIGN STREAM
CLEAR CLEAR
CLOCK_ERROR_ALARM CLOCK ERROR ALARM
COMM_ERROR_ALARM COMMUNICATION ERROR ALARM
COMP_NAME$(table%,component%) COMPONENT NAME
COMP_TYPE$(method%,component%) COMPONENT TYPE
COPY_ARRAY(src_array,dst_array) COPY ARRAY
CUR_METHOD CURRENT METHOD
CUR_STRM CURRENT STREAM
CYCLE_TIME(method%) CYCLE TIME
DACS_EVT_MSG(message$) DACS EVENT MESSAGE
DEACT(stream%) DEACTIVATE STREAM
FLAME_OUT_ALARM FLAME OUT ALARM
GET_ACTUAL_RT(method%,component%) GET ACTUAL RETENTION TIME
GET_ASSIGN(stream%) GET STREAM ASSIGNMENT
GET_BENCH_CONC(method%,component%) GET BENCHMARK CONCENTRATION
GET_CAL_CONC(method%,component%) GET CALIBRATION CONCENTRATION
GET_CC(method%,component%) GET COMPONENT CONCENTRATION
GET_EXPECTED_RT(method%,component%) GET EXPECTED RETENTION TIME
GET_MULTIPLIER_EXP(method%) GET MULTIPLIER EXPONENT
GET_OUTSTANDING_REQUESTS GET OUTSTANDING REQUESTS
GET_PRESS(zone%) GET PRESSURE OF A ZONE
GET_RF(method%,component%) GET RESPONSE FACTOR
GET_TEMP(zone%) GET TEMPERATURE FOR A % OFF
HARDWARE_ALARM HARDWARE ALARM
HIGH_CONC_ALARM HIGH CONCENTRATION ALARM
IDLE_ALARM IDLE ALARM
INJT INJECT TIME
INJT_UCT(T!) INJECT UCT
LOW_CONC_ALARM LOW CONCENTRATION ALARM
N_COMP(method%) NUMBER OF COMPONENTS
N_PEAKS NUMBER OF PEAKS
OFFLINE_ALARM OFFLINE ALARM
OP_MSG_ALARM OPERATOR MESSAGE ALARM
PK_AREA(peak%) PEAK AREA
PK_COMP_NUM(peak%) PEAK COMPONENT NUMBER
PK_CREST_AMP(peak%) PEAK CREST AMPLITUDE
PK_CREST_TIME(peak%) PEAK CREST TIME
PK_END_AMP(peak%) PEAK END AMPLITUDE
PK_END_TIME(peak%) PEAK END TIME
PK_HEIGHT(peak%) PEAK HEIGHT
PK_RAW_AREA(peak%) PEAK RAW AREA
PK_START_AMP(peak%) PEAK START AMPLITUDE
PK_START_TIME(peak%) PEAK START TIME
POSTAN_ERROR_ALARM POST ANALYSIS ERROR ALARM
POWER_FAIL_ALARM POWER FAIL ALARM
PREV_INJT PREVIOUS INJECT TIME
PREV_INJT_UCT(T!) PREVIOUS INJECT UCT
PREV_METHOD PREVIOUS METHOD
PREV_STRM PREVIOUS STREAM
PRG_STRM PURGING STREAM function
PURGE(stream%) PURGING STREAM command