Rockwell Automation Publication 193-UM015E-EN-P - October 2015 527
Metering and Diagnostics Chapter 8
kVARh Generated 10
-3
kVARh Generated 10
-3
(Parameter 94) reports a component of total reactive
energy generated (kVARh). Multiply this value by 10
-3
and add to the other
kVARh Generated parameters.
Represents 000,000,000,000. XXX kVARh
Table 508 - kVARh Generated x 10
-3
(Parameter 94)
kVARh Net 10
9
kVARh Net 10
9
(Parameter 95) reports a component of total reactive energy net
(kVARh). Multiply this value by 10
9
and add to the other kVARh Net
parameters.
Represents XXX,000,000,000.000 kVARh
Table 509 - kVARh Net x 10
9
(Parameter 95)
kVARh Net 10
6
kVARh Net 10
6
(Parameter 96) reports a component of total reactive energy net
(kVARh). Multiply this value by 10
6
and add to the other kVARh Net
parameters.
Represents 000,XXX,000,000.000 kVARh
Default Value 0
Minimum Value -999
Maximum Value 999
Parameter Type INT
Size (Bytes) 2
Scaling Factor 1
Units
Default Value 0
Minimum Value -999
Maximum Value 999
Parameter Type INT
Size (Bytes) 2
Scaling Factor 1
Units