logging events display-location
To enable the alarm source location display field for bistate alarms in the output of the show logging and
show logging events buffer command, use the logging events display-location command in global
configuration mode.
logging events display-location
no logging events display-location
Syntax Description
This command has no keywords or arguments.
Command Default
The alarm source location display field in show logging output is not enabled.
Command Modes
Global configuration
Command History
ModificationRelease
This command was introduced.Release 3.8.0
Usage Guidelines
The output of the show logging command for bistate alarms has been enhanced. Previously, the alarm source
field in the output displayed the location of the process that logged the alarm. Use the logging events
display-location command to configure the output of the show logging command to include an additional
source field that displays the actual source of the alarm. The alarm source is displayed in a format that is
consistent with alarm source identification in other platforms and equipment. The new alarm source display
field aids accurate identification and isolation of the source of a fault.
By default, the output of the show logging command does not include the new alarm source identification
field. If you enable the alarm source location display field in the show logging output, the same naming
conventions are also used to display hardware locations in the show diag and show inventory command
output.
Customer OSS tools may rely on the default output to parse and interpret the alarm output.Note
Task ID
OperationsTask ID
read, writelogging
Cisco IOS XR System Monitoring Command Reference for the Cisco XR 12000 Series Router, Release 4.1
OL-24735-01 29
Alarm Management and Logging Correlation Commands
logging events display-location