load-interval
To specify the interval for load calculation of an interface, use the load-interval command in interface
configuration mode. To reset the load interval to the default setting, use the no form of this command.
load-interval seconds
no load-interval seconds
Syntax Description
Number of seconds for load calculation of an interface. The value range is from 0 to
600 seconds and in increments of 30 (such as 30, 60, 90, and so on). The default is 300
seconds.
seconds
Command Default
seconds: 300 seconds (5 minutes)
Command Modes
Interface configuration
Command History
ModificationRelease
This command was introduced.Release 3.2
Usage Guidelines
When load interval is set to zero, load calculation is disabled. If you set the load interval, you must use a
multiple of 30 (up to 600 seconds).
Task ID
OperationsTask ID
read/writeinterface
Examples
This example shows how to configure the load interval to 30 seconds:
RP/0/0/CPU0:router# configure
RP/0/0/CPU0:router(config)# interface pos 0/1/0/0
RP/0/0/CPU0:router(config-if)# load-interval 30
Cisco IOS XR System Monitoring Command Reference for the Cisco XR 12000 Series Router, Release 4.1
416 OL-24735-01
Statistics Service Commands
load-interval

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco XR 1200 series and is the answer not in the manual?

Cisco XR 1200 series Specifications

General IconGeneral
BrandCisco
ModelXR 1200 series
CategoryNetwork Router
LanguageEnglish

Related product manuals