Page #229 background imageLoading...
Page #229 background image
IPv6 Addressing 229
show ipv6 neighbors
The show ipv6 neighbors Privileged EXEC mode command displays IPv6 neighbor discovery cache
information.
Syntax
show ipv6 neighbors
{
static
|
dynamic
}[
ipv6-address
ipv6-address
] [
mac-address
mac-address
]
static
— Display static neighbor discovery cash entries.
dynamic
— Display dynamic neighbor discovery cash entries.
ipv6-address
— Display the neighbor discovery cache information entry of a specific IPv6 address.
mac-address
— Display the neighbor discovery cache information entry of a specific MAC address.
Command Mode
Privileged EXEC mode.
User Guidelines
The associated interface of a MAC address can be aged out from the FDB table, so the Interface field
can be empty.
When an ARP entry is associated with an IP interface that is defined on a port or port-channel, the
VLAN field is empty.
The possible neighbor cash states are:
INCMP
(Incomplete) — Address resolution is being performed on the entry. Specifically, a Neighbor
Solicitation has been sent to the solicited-node multicast address of the target, but the corresponding
Neighbor Advertisement has not yet been received.
REACH
(Reachable) — Positive confirmation was received within the last ReachableTime
milliseconds that the forward path to the neighbor was functioning properly. While REACHABLE, no
special action takes place as packets are sent.
STALE
— More than ReachableTime milliseconds have elapsed since the last positive confirmation
was received that the forward path was functioning properly. While stale, no action takes place until a
packet is sent.
DELAY
— More than ReachableTime milliseconds have elapsed since the last positive confirmation
was received that the forward path was functioning properly, and a packet was sent within the last
DELAY_FIRST_PROBE_TIME seconds. If no reachability confirmation is received within
DELAY_FIRST_PROBE_TIME seconds of entering the DELAY state, a Neighbor Solicitation is sent
and the state is changed to PROBE.
PROBE
— A reachability confirmation is actively sought by retransmitting Neighbor Solicitations
every RetransTimer milliseconds until a reachability confirmation is received.
book.book Page 229 Thursday, December 18, 2008 7:40 PM

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerConnect 3524 and is the answer not in the manual?

Dell PowerConnect 3524 Specifications

General IconGeneral
Throughput9.5 Mpps
Number of queues4
MAC address table8000 entries
Maximum data transfer rate0.1 Gbit/s
Supported data transfer rates10/100 Mbps
10G supportNo
Number of VLANs256
Flow control supportYes
Networking standardsIEEE 802.1D, IEEE 802.1p, IEEE 802.1Q, IEEE 802.1s, IEEE 802.1w, IEEE 802.3ad
Input frequency50/60 Hz
Weight (imperial)11 lbs
Dimensions (WxDxH)440 x 257 x 43.2 mm
Networking featuresGigabit Ethernet, Fast Ethernet
Authentication methodRADIUS, TACACS+
Connectivity technologyWired
Dimensions (W x D x H) (imperial)17.3 x 10.12 x 1.7 \
Switch typeManaged
Switch layerL2
Data link protocolsEthernet
Supported network protocolsHTTP, HTTPS/SSL, SSH
Power connectorDC-in jack
Gigabit Ethernet (copper) ports quantity2
Basic switching RJ-45 Ethernet ports quantity24
Product colorBlack
Power sourceAC
Input voltage100 - 240 V
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 45 °C
Storage relative humidity (H-H)10 - 95 %
Operating relative humidity (H-H)10 - 90 %
Weight and Dimensions IconWeight and Dimensions
Weight5000 g

Related product manuals