Page #134 background imageLoading...
Page #134 background image
Parameter
description
protocol
Performance
Menu
10
Indicates
that
the
current
limits
are
active.
Indicates
that
power
is
being
transferred
from
the
motor
to
the
supply.
This
parameter
is
one
if
the
pre-ramp
reference
(Pr
1.03
=
{di02,
0.37}
)
is
negative,
and
zero
if
the
pre-ramp
reference
is
zero
or
positive.
This
parameter
is
one
if
the
speed
feedback
(Pr
3.02
=
{di05,
0.40}
)
is
negative,
or
zero
if
the
speed
feedback
is
zero
or
positive.
This
parameter
is
set
if
the
drive
output
current
is
larger
than
105
%
of
rated
current
(Pr
5.07
=
{SE07,
0.28}
)
and
the
overload
accumulator
is
greater
Indicates
that
the
heat
sink
temperature
Pr
7.04
is
above
the
alarm
level.
Indicates
that
one
of
the
drive
alarms
is
active,
i.e.
Pr
10.19
=
Pr
10.17
OR
Pr
10.18
.
Parameter
structure
Keypad and
format
Advanced
parameter
descriptions
Serial comms
than 75 % to warn that if the motor current is not reduced the drive will trip on an Ixt overload. (If the rated current (Pr
5.07
=
{SE07,
0.28}
) is set to a
level above the rated drive current (Pr
11.32
) the overload alarm is given when the current is higher than 100 % of rated current.)
Mentor MP Advanced User Guide
131
Issue Number: 4
www.onxcontrol.com
10.13
Direction
commanded
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
Update
rate
Background write
10.10
Regenerating
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
Update
rate
4 ms write
10.14
Direction
running
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
Update
rate
Background write
10.09
Drive
output
is
at
current
limit
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
Update
rate
4 ms write
10.17
Overload
alarm
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
Update
rate
Background write
10.18
Drive
over
temperature
alarm
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
Update
rate
Background write
10.19
Drive
warning
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
Update
rate
Background write

Table of Contents

Other manuals for Emerson Mentor MP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Mentor MP and is the answer not in the manual?

Emerson Mentor MP Specifications

General IconGeneral
BrandEmerson
ModelMentor MP
CategoryDC Drives
LanguageEnglish

Related product manuals