Page #150 background imageLoading...
Page #150 background image
Parameter
description
protocol
Performance
Menu
11
Note
that
the
drive
holds
its
own
transmitters
active
for
up
to
1
ms
after
it
has
transmitted
data
before
switching
to
the
receive
mode,
the
host
should
The
drive
software
version
consists
of
three
numbers,
xx.yy.zz.
Pr
11.29
=
{di14,
0.49}
)
displays
xx.yy
and
zz
is
displayed
in
Pr
11.34
.
If
any
number
other
than
0
is
programmed
into
this
parameter
user
security
is
applied
so
that
no
parameters
except
(Pr
11.44
=
{SE14,
0.35}
)
can
be
This
parameter
indicates
the
continuous
current
rating
of
the
drive.
See
Pr
11.55
for
more
details.
This
parameter
has
three
possible
values
(480
V,
575
V,
690
V)
and
indicates
the
voltage
rating
of
the
drive.
Parameter
structure
Keypad and
format
Advanced
parameter
descriptions
Serial comms
not send any data during this time.
Modbus RTU uses a silent period detection system to detect the end of a message. This silent period is either the length of time for 3.5 characters at
the present baud rate or the length of time set in Pr
11.26
, whichever is the longest.
Where:
xx specifies a change that affects hardware compatibility
yy specifies a change that affects product documentation
zz specifies a change that does not affect the product documentation.
adjusted with the LED keypad. When this parameter is read via an LED keypad and security is locked it appears as zero. The security code can be
modified via serial comms etc. by setting this parameter to the required value, setting (Pr
11.44
=
{SE14,
0.35}
) to 2 and initiating a reset by setting
Pr
10.38
to 100. However security can only be cleared via the LED keypad.
Mentor MP Advanced User Guide
147
Issue Number: 4
www.onxcontrol.com
11.29
{di14,
0.49}
Software
version
Coding
Bit
SP
FI
DE
TE
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
2
1
1
1
1
Range
1.00 to 99.99
Update
rate
Write at power-up
11.30
User
security
code
Coding
Bit
SP
FI
DE
TE
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
1
1
Range
0 to 999
Default
0
Update
rate
Background read
11.33
Drive
voltage
rating
Coding
Bit
SP
FI
DE
TE
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
1
Range
0 (480 V) , 1 (575 V), 2 (690 V)
Update
rate
Write at power-up
11.32
Current
rating
Coding
Bit
SP
FI
DE
TE
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
1
Range
0.00 to 10000.0 A
Update
rate
Write at power-up
Pr
11.26
Action
0
The
transmit
buffers
are
turned
on
and
data
transmission
begins
immediately
1
The
transmit
buffers
are
turned
on
and
data
transmission
begins
after
1
ms
2 or more
The
transmit
buffers
are
turned
on
after
an
additional
delay
of
(Pr
11.26
-1)
ms
and
data
transmission begins after a further 1 ms delay

Table of Contents

Other manuals for Emerson Mentor MP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Mentor MP and is the answer not in the manual?

Emerson Mentor MP Specifications

General IconGeneral
BrandEmerson
ModelMentor MP
CategoryDC Drives
LanguageEnglish

Related product manuals