Page #156 background imageLoading...
Page #156 background image
Parameter
description
protocol
Performance
Menu
11
This
parameter
controls
access
via
the
drive
LED
keypad
as
follows:
The
LED
keypad
can
adjust
this
parameter
even
when
user
security
is
set.
When
this
bit
is
set
to
one
the
motor
2
parameters
in
menu
21
become
active
instead
of
the
equivalent
parameters
in
other
menus.
Changes
will
only
Displays
the
last
loaded
defaults.
This
parameter
is
used
to
start
and
stop
the
drive
Onboard
Application
Lite
program.
The
Drive
Onboard
Application
Lite
Ladder
Program
Status
parameter
indicates
to
the
user
the
actual
state
of
the
drive
Onboard
Application
Lite
Parameter
structure
Keypad and
format
Advanced
parameter
descriptions
Serial comms
be implemented when the drive is disabled. When the motor 2 parameters are active the decimal point that is second from the right on the 1st row of
the display is lit. If this parameter is one when an autotune is carried out (Pr
5.12
= 1), the results of the autotune are written to the equivalent second
motor parameters instead of the normal parameters. Each time this parameter is changed the accumulator for motor thermal protection is reset to
zero.
Ladder Program. (not installed / running / stopped / tripped.)
Mentor MP Advanced User Guide
153
Issue Number: 4
www.onxcontrol.com
11.46
Defaults
previously
loaded
Coding
Bit
SP
FI
DE
TE
VM
DP
ND
RA
NC
NV
PT
US
R
W
BU
PS
1
1
1
1
Range
0 to 2
Default
0
Update
rate
Background write
11.47
Drive
Onboard
Application
Lite
Ladder
Program
Enable
Coding
Bit
SP
FI
DE
TE
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Range
0 to 2
Default
2
Update
rate
Background read
Value
Description
0
Halt
the
Drive
Onboard
Application
Lite
ladder
Program.
1
Run
the
Drive
Onboard
Application
Lite
ladder
Program
(if
installed).
Any
out-of-range
parameter writes attempted will be clipped to the maximum / minimum values valid for that
parameter before being written.
2
Run
the
drive
Onboard
Application
Lite
ladder
Program
(if
installed).
Any
out-of-range
parameter writes attempted will cause a drive trip.
11.48
Drive
Onboard
PLC
program
status
Coding
Bit
SP
FI
DE
TE
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Range
-128 to +127
Update
rate
Background write
11.45
Motor
2
parameters
select
Coding
Bit
SP
FI
DE
TE
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Default
0
Update
rate
Background read
Value
String
Action
0
L1
Only
menu
0
can
be
accessed
1
L2
All
menus
can
be
accessed
2
Loc
Lock
user
security
when
drive
is
reset.
(This parameter is set to L1 after reset)

Table of Contents

Other manuals for Emerson Mentor MP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Mentor MP and is the answer not in the manual?

Emerson Mentor MP Specifications

General IconGeneral
BrandEmerson
ModelMentor MP
CategoryDC Drives
LanguageEnglish

Related product manuals