be implemented when the drive is disabled. When the motor 2 parameters are active the decimal point that is second from the right on the 1st row of
the display is lit. If this parameter is one when an autotune is carried out (Pr
5.12
= 1), the results of the autotune are written to the equivalent second
motor parameters instead of the normal parameters. Each time this parameter is changed the accumulator for motor thermal protection is reset to
zero.
Ladder Program. (not installed / running / stopped / tripped.)
Mentor MP Advanced User Guide
153
Issue Number: 4
www.onxcontrol.com
11.46
parameter writes attempted will be clipped to the maximum / minimum values valid for that
parameter before being written.