2
Parameter
Parameter
description
protocol
Performance
The
jog
acceleration
rate
is
only
used
when
accelerating
towards
the
jog
reference
and
when
changing
the
jog
reference.
The
acceleration
rate
is
selected
as
follows:
such
that
ramp
rates
can
be
selected
by
external
control.
The
ramp
rate
selected
depends
on
the
bi
nary
code
generated
by
these
bits
as
follows:
When
Pr
2.20
is
set
to
9
the
appropriate
deceleration
rate
is
automatically
selected
depending
on
the
value
of
Pr
1.50
,
and
so
a
deceleration
rate
can
structure
Keypad and
format
Advanced
parameter
descriptions
Serial comms
NOTE
Using low values (e.g. 0.100), can cause FbL trips. To avoid trips, increase Pr
3.56
Speed feedback loss window.
0
Ramp rate selection by terminal input
1-8
Ramp rate defined by parameter number, i.e. 1 = Pr
2.21
{
SE04,
0.25
}, 2 = Pr
2.22
, etc.
9
Ramp rate selection by Pr
1.50
When Pr
2.20
is set to 0 the deceleration ramp rate selected depends on the state of bit Pr
2.35
to Pr
2.37
. These bits are for control by digital inputs
be programmed to operate with each reference. Since the new ramp rate is selected with the new reference, the deceleration applies towards the
selected preset if the motor needs to decelerate to reach the preset.
38
Mentor MP Advanced User Guide
www.onxcontrol.com
Issue Number: 4
2.11
{SE03,
0.24}
Acceleration
rate
1
2.12
Acceleration
rate
2
2.13
Acceleration
rate
3
2.14
Acceleration
rate
4
2.15
Acceleration
rate
5
2.16
Acceleration
rate
6
2.17
Acceleration
rate
7
2.18
Acceleration
rate
8
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
3
1
1
1
Range
0 to MAX_RAMP_RATE s / (Pr
1.06
{
SE02,
0.23
} or Pr
2.39
)
Default
5.000
Second
motor
parameter
Pr
21.04
for Pr
2.11
{
SE03,
0.24
} only
Update
rate
4 ms read
2.19
Jog
acceleration
rate
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
3
1
1
1
Range
0 to MAX_RAMP_RATE s / (Pr
1.06
{
SE02,
0.23
} or Pr
2.39
)
Default
5.000
Update
rate
Background read
2.20
Deceleration
rate
selector
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Range
0 to 9
Default
0
Update
rate
4 ms read
Pr
2.37
Pr
2.36
Pr
2.35
Ramp
defined
by
0
0
0
Pr
2.21
{
SE04,
0.25
}
0
0
1
Pr
2.22
0
1
0
Pr
2.23
0
1
1
Pr
2.24
1
0
0
Pr
2.25
1
0
1
Pr
2.26
1
1
0
Pr
2.27
1
1
1
Pr
2.28

Table of Contents

Other manuals for Emerson Mentor MP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Mentor MP and is the answer not in the manual?

Emerson Mentor MP Specifications

General IconGeneral
BrandEmerson
ModelMentor MP
CategoryDC Drives
LanguageEnglish

Related product manuals