Parameter
x.00
Parameter
protocol
Performance
Indicates
which
bridge
in
a
12
or
24
parallel
system
has
been
requested.
This
has
to
be
sent
via
digital
I/O
or
field
bus.
The
bridge
status
of
the
other
drives
in
a
12
or
24
parallel
system
have
to
be
sent,
via
digital
I/O
or
field
bus,
to
these
parameters.
When
digital
I/O
is
When
this
parameter
is
set,
the
flux
feedback
is
taken
from
Pr
5.89
.
This
has
been
made
available
w
here
the
field
flux
is
provided
by
an
independent
The
value
resulting
from
the
application
of
Pr
5.61
to
the
filtered
current.
The
calculated
motor
back
emf
based
on
armature
voltage
minus
the
IR
drop
(Pr
5.52
).
Flux
feedback
after
the
current
to
flux
converter,
see
motor
saturation
breakpoints
(Pr
5.29
and
Pr
5.30
).
Menu
5
Parameter
structure
Keypad and
description format
Advanced
parameter
descriptions
Serial comms
setup to use Pr
5.45
to Pr
5.47
the software reads and writes to the I/O at 1 ms.
external controller (not FXMP25).
86
Mentor MP Advanced User Guide
www.onxcontrol.com
Issue Number: 4
5.48
External
flux
feedback
select
Coding
Bit
SP
FI
DE
TE
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Default
0
Second
motor
parameter
Pr
21.38
Update
rate
1 ms read
05.45
05.46
05.47
Slave
bridge
request
status
Coding
Bit
SP
FI
DE
TE
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
Range
0 to 1
Update
rate
1 ms read
05.44
Bridge
request
output
Coding
Bit
SP
FI
DE
TE
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
Range
0 to 1
Update
rate
1 ms write
5.52
IR
drop
Coding
Bit
SP
FI
DE
TE
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
1
Range
+/-
ARMATURE_VOLTAGE_MAX
Vdc
Update
rate
Background write
5.53
Back
emf
Coding
Bit
SP
FI
DE
TE
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
1
Range
+/-
ARMATURE_VOLTAGE_MAX
Vdc
Update
rate
Background write
5.54
Flux
feedback
Coding
Bit
SP
FI
DE
TE
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
1
Range
±150.0
%
Update
rate
Background write

Table of Contents

Other manuals for Emerson Mentor MP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Mentor MP and is the answer not in the manual?

Emerson Mentor MP Specifications

General IconGeneral
BrandEmerson
ModelMentor MP
CategoryDC Drives
LanguageEnglish

Related product manuals