Menu
5
Parameter
structure
Keypad and
description format
Advanced
parameter
descriptions
Serial comms
depends upon the setting of the rated current Pr
5.70
{
SE10,
0.31
}.
MAX_FIELD_FLUX = 100 x 25 /
Pr
5.70
{
SE10,
0.31
}.
For values of Pr
5.70
{
SE10,
0.31
} less than 20.8A the MAX_FIELD_FLUX will be limited to 120 %.
This parameter becomes the maximum voltage demand when field voltage mode is selected Pr
5.75
= On (1).
This parameter becomes the minimum voltage demand when field voltage mode is selected Pr
5.75
= On (1).
NOTE
If Flux feedback is selected from Pr
5.89
and the value falls below that of the value set in Pr
5.69
, then no action can be taken by the drive as it does
not control the Flux demand.
90
Mentor MP Advanced User Guide
www.onxcontrol.com
Issue Number: 4
5.70
Size 2A&B - Eur: 3A, USA: 20A
Size 2C&D - Eur: 5A, USA: 20A
Second
motor