Parameter
description
protocol
Performance
Menu
1
This
parameter
defines
the
time
between
preset
reference
changes
when
Pr
1.15
is
set
to
9.
If
Pr
1.48
is
set
to
1
then
the
preset
counter
and
timer
are
The
drive
can
be
controlled
from
the
keypad
if
Pr
1.14
{
SE05,
0.26
}
is
set
to
4.
The
Stop
and
Run
keys
automatically
become
active
(the
Reverse
key
See
below.
The
speed
reference
resolution
is
restricted
to
0.1
rpm
from
normal
parameters,
but
the
resolution
can
be
improved
by
using
the
precision
reference.
When
this
bit
is
at
0
the
precision
reference
parameters
are
read
and
stored
in
internal
memory.
Because
the
precision
reference
has
to
be
set
in
two
Parameter
structure
Keypad and
format
Advanced
parameter
descriptions
Serial comms
reset and preset 1 will be selected.
may be optionally enabled with Pr
6.13
). The speed reference is defined by Pr
1.17
. This is a read only parameter that can only be adjusted in status
mode by pressing the Up or Down keys. If keypad control mode is selected, then pressing the Up or Down keys in status mode will cause the drive to
automatically display the keypad reference and adjust it in the relevant direction. This can be done whether the drive is disabled or running. If the Up
or Down keys are held the rate of change of keypad reference increases with time. The units used for to display the keypad reference for different
modes are given below.
See also Pr
1.51
on page 33 (Power-up keypad control mode reference).
Pr
1.18
defines the coarse part of reference (either positive or negative) with a resolution of 0.1 rpm and Pr
1.19
defines the fine part of the reference
(always positive) with a resolution of 0.001 rpm. The final reference is given by Pr
1.18
+ Pr
1.19.
Therefore Pr
1.19
increases positive references
away from zero, and decreases negative references towards zero.
parameters, this bit is provided to prevent the drive reading the parameters while the reference is being updated. Instead, the drive uses the value
stored in memory preventing the possibility of data skew.
Mentor MP Advanced User Guide
29
Issue Number: 4
www.onxcontrol.com
1.16
Preset
reference
selector
timer
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
Range
0 to 400.0 s
Default
10.0
Update
rate
Background read
1.17
Keypad
control
mode
reference
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
1
Range
±MAX_SPEED_REF rpm
Default
0.0
Update
rate
4 ms read
1.18
Precision
reference
coarse
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
Range
±MAX_SPEED_REF rpm
Default
0.0
Update
rate
Background read
1.19
Precision
reference
fine
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
3
1
1
1
Range
0 - 0.099 rpm
Default
0.000
Update
rate
Background read
1.20
Precision
reference
update
disable
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Default
0
Update
rate
Background read

Table of Contents

Other manuals for Emerson Mentor MP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Mentor MP and is the answer not in the manual?

Emerson Mentor MP Specifications

General IconGeneral
BrandEmerson
ModelMentor MP
CategoryDC Drives
LanguageEnglish

Related product manuals