initialized. The drive cannot be enabled until this parameter is one.
If any trips occur that could indicate that the encoder system is no longer initialized correctly (i.e. Enc2), or the encoder power supplies are overloaded
(i.e. Enc1), Pr
3.48
is set to zero and the drive cannot be enabled until the encoder is re-initialized. It is likely that the failure of either of these supplies
will cause one of the other encoder trips and it should be noted that Enc1 or PS.24V trips can override Enc2 trips so that the power supply overload is
not mistaken for an encoder error.
to trim out the tolerance build ups in the feedback electronics. Parameter units are DC in DC mode and rms AC in AC mode.