EasyManuals Logo
Home>Emerson>DC Drives>Mentor MP

Emerson Mentor MP User Manual

Emerson Mentor MP
222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #63 background imageLoading...
Page #63 background image
Menu
4
Parameter
Parameter
descript
ion
protocol
Performance
The
current
feedback
signal
is
derived
from
internal
current
transformers.
It
is
used
for
current
control
and
indication
of
the
armature
current,
and
to
The
value
of
the
current
magnitude
parameter
filtered
over
the
last
6
mains
cycles.
The
torque
demand
can
be
derived
from
the
speed
controller
and/or
the
torque
reference
and
offset.
The
units
of
the
torque
demand
are
%
of
rated
The
current
demand
is
derived
from
the
torque
demand.
Provided
the
motor
is
not
in
current
limit,
the
torque
and
current
demands
are
the
same
and
The
motoring
current
limit
applies
in
either
direction
of
rotation
when
the
machine
is
producing
motoring
torque.
The
regen
current
limit
applies
in
either
direction
when
the
machine
is
producing
regenerating
torque.
structure
Keypad and
format
Advanced
parameter
descriptions
Serial comms
initiate motor protection.
torque.
the drive is not operating in the field weakening region.
60
Mentor MP Advanced User Guide
www.onxcontrol.com
Issue Number: 4
4.06
Regen
current
limit
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
1
Range
0 to MOTOR1_CURRENT_LIMIT_MAX %
Default
150.0
Second
motor
parameter
Pr
21.28
Update
rate
Background read
4.05
Motoring
current
limit
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
1
Range
0 to MOTOR1_CURRENT_LIMIT_MAX %
Default
150.0
Second
motor
parameter
Pr
21.27
Update
rate
Background read
4.03
{di07,
0.42}
Torque
demand
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
1
1
Range
±TORQUE_PROD_CURRENT_MAX %
Update
rate
4 ms write
4.01
Current
magnitude
{di08,
0.43}
Coding
Bit
SP
FI
1
DE
Txt
VM
1
DP
2
ND
1
RA
NC
1
NV
PT
1
US
RW
BU
1
PS
Range
± DRIVE_CURRENT_MAX A
Update
rate
4 ms write
4.02
Filtered
current
magnitude
Coding
Bit
SP
FI
1
DE
Txt
VM
1
DP
2
ND
1
RA
NC
1
NV
PT
1
US
RW
BU
1
PS
Range
± DRIVE_CURRENT_MAX A
Update
rate
4 ms write
4.04
Current
demand
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
1
Range
±TORQUE_PROD_CURRENT_MAX %
Update
rate
4 ms write

Table of Contents

Other manuals for Emerson Mentor MP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Mentor MP and is the answer not in the manual?

Emerson Mentor MP Specifications

General IconGeneral
BrandEmerson
ModelMentor MP
CategoryDC Drives
LanguageEnglish

Related product manuals