Menu
12
Parameter
Parameter
description
protocol
Performance
The
variable
selectors
allow
two
source
values
(defined
by
Pr
12.08
,
Pr
12.28
and
Pr
12.09
,
Pr
12.29
)
to
be
combined
as
defined
by
the
mode
It
is
active
when
the
control
has
a
non-zero
value.
structure
Keypad and
format
Advanced
parameter
descriptions
Serial comms
(Pr
12.10
, Pr
12.30
) to produce an output (Pr
12.12
, Pr
12.32
) which can be routed to the destination parameter (defined by Pr
12.11
, Pr
12.31
). The
actions of the variable selector are defined by the mode parameter as given below. If the mode parameter is changed or the variable selector is
disabled because neither source is routed to a valid parameter all the internal state variables (i.e. filter accumulator, etc.) within the selector are reset.
When the Sectional control mode is selected the function is also reset, and the output is held at zero, when the control (Pr
12.15
or Pr
12.35
) is zero.
Sectional
control
The sectional control function is intended to apply scaling and a speed offset to a 16 bit position value to generate a new 16 bit position value. The
output can be used as an input to the position controller (menu 13) or to generate an encoder simulation output via the SM-Universal encoder plus
module. This function can be selected for either variable selector, but the description below relates to variable selector 1.
Position
input
d/dt
4
.000 + 12.13
4.000
Speed
input
12.14
Accumulator
%
Position
output
The position input can be derived from any parameter, however it is intended to be used with a position value that has a range from 0 to 65535. The
input is scaled so that as Pr
12.13
is varied between -4.000 and 4.000 the proportion of the input position change added to the accumulator varies
from 0.000 to 2.000 (i.e. the change of position input value is added without scaling if Pr
12.13
is 0.000). The remainder from the scaling division is
stored and then added at the next sample to maintain an exact ratio between the position input and the position output, provided the speed input is
zero. The controller only takes the change of position from the input source parameter, and not the absolute value, so that when the controller is first
made active the output does not jump to the source position, but only moves with any changes of source position after that point in time.
The range of the output of the accumulator is 0.00 % and 100.00 %. Unlike other functions the value is not simply limited, but rolls under or over
respectively. Although the output destination can be any parameter it is intended to be used with a position value that has a range from 0 to 65535.
The speed input defines a speed offset with a resolution of 0.1 rpm. Full scale of the source parameter corresponds to 1000.0 rpm. Scaling may be
applied using Pr
12.14
to give a full scale value of 4000.0 rpm. The speed input is added to the accumulator to move the output position forwards or
backwards with respect to the position input.
164
Mentor MP Advanced User Guide
www.onxcontrol.com
Issue Number: 4
Mode
value
Action
Result
0
Select
input
1
output
=
input1
1
Select
input
2
output
=
input2
2
Add
output
=
input1
+
input2
3
Subtract
output
=
input1
-
input
2
4
Multiply
output
=
(input1
x
input2)
/
100.0
5
Divide
output
=
(input1
x
100.0)
/
input2
6
filter
output
=
input1
/
((control
param)s
+
1)
7
Linear ramp
output
=
input1
via
a
ramp
with
a
ramp
time
of
(control
param) seconds from 0 to 100 %
8
Modulus
output
=
|
input1
|
9
Powers
2
control = 0.02:
output = input1
/ 100.0
3 2
control = 0.03: output = input1
/ 100.0
control has any other value: output = input1
10
Sectional control
control
=
0.00:
disabled,
accumulator
reset
and
output
zero control <> 0.00: output as defined below
12.15
Variable
selector
1
control
12.35
Variable
selector
2
control
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
2
1
1
1
Range
0.00 to 100.00
Default
0.00
Update
rate
Background

Table of Contents

Other manuals for Emerson Mentor MP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Mentor MP and is the answer not in the manual?

Emerson Mentor MP Specifications

General IconGeneral
BrandEmerson
ModelMentor MP
CategoryDC Drives
LanguageEnglish

Related product manuals