EasyManuals Logo
Home>Emerson>DC Drives>Mentor MP

Emerson Mentor MP User Manual

Emerson Mentor MP
222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #55 background imageLoading...
Page #55 background image
Menu
3
Parameter
Parameter
description
protocol
Performance
The
terminations
may
be
enabled/disabled
by
this
parameter
as
follows:
Trips
can
be
enabled/disabled
using
Pr
3.40
as
follows:
Encoder
trips
+These
trips
can
be
enabled/disabled
by
Pr
3.40
encoder
types
either
directly
or
indirectly
as
listed
below.
Power
supply
short
circuit
or
overload
on
drive
encoder
terminals
structure
Keypad and
format
Advanced
parameter
descriptions
Serial comms
The following table shows trips that can be initiated that are related to the drive encoder feedback and whether they can be enabled and disabled by
Pr
3.40
.
1.
If the terminations are not enabled on the A,
B or Z inputs the wire break system will not operate (5 V or 8 V only). (Note that as default the Z
input terminations are disabled to disable wire break detection on this input.)
Wire-break
detection
It may be important to detect a break in the connections between the drive and the position feedback device. This feature is provided for most
There is an overload or short circuit on the drive encoder terminals.
Power
supply
short
circuit
or
overload
on
option
encoder
supply
There is an overload or short circuit on the option encoder power supply.
Both the above trips can over ride trip Enc2 so if there is a wire break trip and then a power supply trip the drive will store both trips in the trip log. Both
the above trips turn the terminal encoder supply off.
52
Mentor MP Advanced User Guide
www.onxcontrol.com
Issue Number: 4
3.39
{Fb08,
0.78}
Drive
encoder
termination
select
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
Range
0 to 2
Default
1
Update
rate
Background read
3.40
Drive
encoder
error
detection
level
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Range
0 to 2
Default
0
Update
rate
Background read
Reason
for
error
Drive
trip
Power
supply
short
circuit
or
overload
on
drive
encoder
terminals
Enc1
(1)
+Hardware wire-break detect on A, B and Z inputs
Enc2
Power
supply
short
circuit
or
overload
on
option
encoder
supply
Enc3
Speed
feedback
selected
from
an
option
slot
that
does
not
have
a
position
feedback category Solutions Module installed
Enc9
Termination
Overload
Enc10
Bit
Function
0
Wire
break
detect
disabled
1
Wire
break
detect
on
A
and
B
(need
termination
enabled
for
5
V
and
8
V)
2
Wire
break
detect
on
A,
B
and
Z
(need
termination
enabled
for
5
V
signals)
Encoder
input
Pr
3.39=0
Pr
3.39=1
Pr
3.39=2
A
-
A
\
Di
sabled
Enabled
Enabled
B
-
B
\
Disabled
Enabled
Enabled
Z
-
Z
\
Disabled
Disabled
Enabled
Device
Detection
method
Drive
Trip
Ab,
Fd,
Fr
Hardware
detectors
on
the
A(F),
B(D,R)
and
Z
signal
detect
a
wire
break
Enc2

Table of Contents

Other manuals for Emerson Mentor MP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Mentor MP and is the answer not in the manual?

Emerson Mentor MP Specifications

General IconGeneral
BrandEmerson
ModelMentor MP
CategoryDC Drives
LanguageEnglish

Related product manuals