Parameter structure
Keypad and display
Parameter x.00
Parameter
description
protocol
Performance
Table
5
-
1
Menu
descriptions
Table
5
-
2
Key
to
parameter
coding
Defaul
t
abbreviations:
format
Advanced
parameter
descriptions
Serial comms
5
Advanced
parameter
descriptions
5.1
Overview
Table 5-2 gives a full key of the coding which appears in the following
parameter tables.
Eur>
European default value
USA>
USA default value
NOTE
Parameter numbers shown in brackets {...} are the equivalent sub block/
Coding
Attribute
{X.XX}
Copied
Menu
0
or
advanced
parameter
Bit
1
bit
parameter:
‘On’
or
‘OFF’
on
the
display
Bi
Bipolar
parameter
Uni
Unipolar
parameter
Txt
Text:
the
parameter
uses
text
strings
instead
of
numbers.
SP
Spare:
not
used
FI
Filtered:
some
parameters
which
can
have
rapidly
changing
values are filtered when displayed on the drive keypad for
easy viewing.
DE
Destination
pointer
parameter:
This
parameter
can
be
used
to set up the location (i.e. menu/parameter number) where
the destination data is to be routed.
VM
Variable
maximum:
the
maximum
of
this
parameter
can
vary.
DP
Decimal
place:
indicates
the
number
of
decimal
places
used
by this parameter.
ND
No
default:
when
defaults
are
loaded
(except
when
the
drive
is manufactured or on EEPROM failure) this parameter is
not modified.
RA
Rating
dependant:
this
parameter
is
likely
to
have
different
values and ranges with drives of different voltage and
current ratings. Parameters with this attribute will not be
transferred to the destination drive by a SMARTCARD when
the rating of the destination drive is different from the source
drive if the drive voltage ratings are different or the file is a
parameter file. However, the value will be transferred if only
the current rating is different and the file is a differences
from default type file.
NC
Not
copied:
not
transferred
to
or
from
SMARTCARD
during
copying.
NV
Not
visible:
not
visible
on
the
keypad.
PT
Protected:
cannot
be
used
as
a
destination.
US
User
save:
saved
in
drive
EEPROM
when
the
user
initiates
a parameter save.
RW
Read/write:
can
be
written
by
the
user.
RO
Read
only:
can
only
be
read
by
the
user
BU
Bit
default
one/unsigned:
Bit
parameters
with
this
flag
set
to
one have a default of one (all other bit parameters have a
default of zero. Non-bit parameters are unipolar if this flag is
one.
PS
Power-down
save:
parameter
automatically
saved
in
drive
EEPROM when the under volts (UV) trip occurs. Power-
down save parameters are also saved in the drive when the
user initiates a parameter save.
Menu
Function
1
Speed
reference
selection,
limits
and
filters
2
Ramps
3
Speed
feedback
and
speed
control
4
Torque
and
current
control
5
Motor
and
field
control
6
Sequencer
and
clock
7
Analog
I/O
8
Digital
I/O
9
Programmable
logic
and
motorized
pot
10
Drive
status
and
trip
information
11
General
drive
setup
12
Threshold
detectors,
variable
selectors
and
brake
control function
13
Position
control
14
User
PID
controller
15
Slot
1
Solutions
Module
menu
16
Slot
2
Solutions
Module
menu
17
Slot
3
Solutions
Module
menu
18
User
application
menu
1
(saved
in
drive
EEPROM)
19
User
application
menu
2
(saved
in
drive
EEPROM)
20
User
application
menu
3
(not
saved
in
drive
EEPROM)
21
Second
motor
parameters
22
Additional
Menu
0
set
up
23
Header
selections

Table of Contents

Other manuals for Emerson Mentor MP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Mentor MP and is the answer not in the manual?

Emerson Mentor MP Specifications

General IconGeneral
BrandEmerson
ModelMentor MP
CategoryDC Drives
LanguageEnglish

Related product manuals