Parameter
description
protocol
Performance
Menu
3
If
the
speed
feedback
(Pr
3.02
{
di05,
0.40
})
exceeds
this
level
in
either
direction
an
overspeed
trip
is
produced.
If
this
parameter
is
set
to
zero,
the
"At
speed"
flag
(Pr
10.06
)
is
set
if
the
speed
feedback
(Pr
3.02
{
di05,
0.40
})
is
on
the
boundaries
or
within
the
at
speed
window.
Flags
Pr
10.07
and
Pr
See
the
description
under
Pr
3.16
.
See
the
description
under
Pr
3.16
Parameter
structure
Keypad and
format
Advanced
parameter
descriptions
Serial comms
overspeed threshold is automatically set to 1.2 x SPEED_MAX.
10.05
are set if the reference is above or below the window respectively.
If Pr
3.09
= 0 reference window mode is used and the "at speed" condition is true if
(|Pr
1.03
{
di02,
0.37
}| - Pr
3.06
) δ |Pr
3.02
{
di05,
0.40
}| δ (|Pr
1.03
{
di02,
0.37
}| + Pr
3.07
)
(If the lower limit is less than zero then zero is used as the lower limit.)
If Pr
3.09
= 1 absolute window mode is used and the "at speed" condition is true if
Pr
3.06
δ |Pr
3.02
{
di05,
0.40
}| δ Pr
3.07
Mentor MP Advanced User Guide
45
Issue Number: 4
www.onxcontrol.com
3.10
{SP01,
0.61}
(Kp1)
Speed
controller
proportional
gains
(Kp2)
3.13
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
4
1
1
1
Range
0.0000 to 6.5535 (1 / (rad/s))
Default
0.0300
Second
motor
parameter
Pr
21.17
(3.10)
Update
rate
Background read
3.11
{SP02,
0.62}
(Ki1)
Speed
controller
integral
gains
(Ki2)
3.14
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
2
1
1
1
Range
0.00 to 655.35 (s / (rad/s))
Default
0.10
Second
motor
parameter
Pr
21.18
(3.11)
Update
rate
Background read
3.08
Overspeed
threshold
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
P
T
US
RW
BU
PS
1
1
1
Range
0 to 10,000 rpm
Default
0
Update
rate
Background read
3.09
Absolute
“at
speed”
select
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Default
0
Update
rate
Background read

Table of Contents

Other manuals for Emerson Mentor MP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Mentor MP and is the answer not in the manual?

Emerson Mentor MP Specifications

General IconGeneral
BrandEmerson
ModelMentor MP
CategoryDC Drives
LanguageEnglish

Related product manuals