A-8
Example of NX Unit Setting Using NX
Configuration Object Service
You can change the NX Unit settings by using the NX Configuration object service.
This section provides examples of the procedure for NX Unit setting using the NX Configuration object
service.
Refer to 8-5-3 NX Configuration Object (Class ID: 74 hex) on page 8-50 for details on the NX Configu-
ration object.
The following three types of procedure are given as the examples.
• Changing the Unit operation settings for a singe NX Unit.
• Changing the Unit operation settings for multiple NX Units.
• Initializing the Unit operation settings for a singe NX Unit.
Precautions for Correct Use
Refer to 16-2 Checking Status with the Network Configurator on page 16-3 for troubleshooting
errors that may occur while setting NX Units using the NX Configuration object service.
Version Information
You can perform the NX Unit setting using the NX Configuration object service only with NX102
CPU Units.
A-8-1
Changing the Unit Operation Settings for Singe NX Unit
Change the Unit operation settings for a single NX Unit mounted to the Controller. In this example, the
unit number of the NX Unit is 1.
The following table gives the setting procedure.
Step Description
CIP Object to use
Class ID Instance ID Service code
Unit
number
1 Change the parameter write
mode of the NX Unit to W
rite
mode.
0x74
NX Configuration
object
0x01 0x37
Switch parameter
write mode
0x01
2 Write values to the NX object
of the NX Unit.
0x74
NX Configuration
object
0x01 0x34
W
rite NX object
0x01
3 Save the values that are set in
the NX Unit.
0x74
NX Configuration
object
0x01 0x36
Save parameter
0x01
4 Restart the NX Unit. 0x74
NX Configuration
object
0x01 0x35
Restart NX unit
0x01
Appendices
A-62
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User’s Manual (W506)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron NX102-12 Series and is the answer not in the manual?

Omron NX102-12 Series Specifications

General IconGeneral
BrandOmron
ModelNX102-12 Series
CategoryController
LanguageEnglish

Related product manuals