Main SP Tables-2
SP2-XXX (Drum)
2005
[Charge DC Voltage]
Adjusts the DC component of the charge roller bias in the print modes.
001 Plain: Bk *ENG [0 to 1000 / 590 / 10 -V/step]
002 Plain: C *ENG [0 to 1000 / 590 / 10 -V/step]
003 Plain: M *ENG [0 to 1000 / 590 / 10 -V/step]
004 Plain: Y *ENG [0 to 1000 / 590 / 10 -V/step]
2006
[Charge AC Voltage]
Adjusts the AC component of the charge roller bias in the print modes.
001 Plain: Bk *ENG [0 to 3000 / 2100 / 10V/step]
002 Plain: C *ENG [0 to 3000 / 2100 / 10V/step]
003 Plain: M *ENG [0 to 3000 / 2100 / 10V/step]
004 Plain: Y *ENG [0 to 3000 / 2100 / 10V/step]
2007
[Charge AC Current: LL]
Displays/sets the AC current target of the charge roller for LL environment (Low
temperature and Low humidity).
001 Environmental Target: Bk *ENG [0 to 2000 / 600 / 10uA/step]
002 Environmental Target: C *ENG [0 to 2000 / 600 / 10uA/step]
003 Environmental Target: M *ENG [0 to 2000 / 600 / 10uA/step]
004 Environmental Target: Y *ENG [0 to 2000 / 600 / 10uA/step]
3. SP Mode Tables
66